• 8kW Hybrid Solar Inverter | 2 MPPT | 10400W PV Input | 8000W Output | BSLBATT
    8kW Hybrid Solar Inverter | 2 MPPT | 10400W PV Input | 8000W Output | BSLBATT
    The BSL-8K-2P is an 8kW hybrid solar inverter with an AC grid output, combining grid-tied and off-grid functions, with two built-in charge controllers with a maximum input current of 22A, no transformer required, and a multifunctional power station combining solar, national grid, generator, and battery energy.
    Inquire
    • BSL-8K-2P
    • BSLBATT
    • Product Description
    Product Description

    This 8kW hybrid solar inverter is compatible with low-voltage 48V solar cells and, in addition to the power upgrade, is equipped with the ability to connect to a generator for both AC-coupled and DC-coupled systems. Whether a new solar system is being added or an old one is being retrofitted, the BSL-8K-2P will serve to optimize energy use and reduce power costs.


    Product Performance:


    10400W photovoltaic input, 8000W AC output

    Up to 6 units can be connected in parallel

    Up to 48kW three-phase solar system

    Compatible with all BSL 48V LiFePO4 batteries

    APP intelligent control

    WIFI module remote upgrade

    Built-in 2 MPPT


    Operating Mode:


    Grid-connected mode

    Off-grid mode

    Backup power mode

    Peak-shaving and valley-filling


    ModelBSL-8K-2P 8kW Hybrid Solar Inverer
    Battery Input Data
    Battery TypeLithium / Lead-Acid
    Nominal Battery Voltage (V)51.2
    Battery Voltage Range (V)41.6 ~ 58.5
    Max. Continuous Charging Current (A) 190
    Max. Continuous Discharging Current (A)190
    Max. Charge Power (W)9200
    Max. Discharge Power (W)9200
    PV String Input Data
    Max. Input Power (W)10400
    Max. Input Voltage (V)500
    MPPT Operating Voltage Range (V)120-430
    Start-up Voltage (V)150
    Nominal Input Voltage (V)360
    Max. Input Current per MPPT (A)22
    Max. Short Circuit Current per MPPT (A)30
    Number of MPPT Trackers2
    Number of Strings per MPPT2
    AC Output Data (On-grid)
    Nominal Apparent Power Output to Utility Grid (W)8000
    Max. Apparent Power Output to Utility Grid (VA)8000
    Max. Apparent Power from Utility Grid (VA)8000
    Nominal Output Voltage (V)230 / 120
    Nominal AC Grid Frequency (Hz)50 / 60
    Max. AC Current Output to Utility Grid (A)38.5
    Max. AC Current From Utility Grid (A)38.5
    Type of InfeedSplit-phase
    Max. Total Harmonic Distortion<3%
    Power Factor~0.99 (Adjustable from 0.8 leading to 0.8 lagging)
    Switch Time<10 ms
    AC Output Data (Back-up)
    Back-up Nominal Apparent Power (W)8000
    Max. Output Apparent Power (VA)8000
    Max. Output Current (A)38.5
    Nominal Output Voltage (V)230 / 120
    Nominal Output Freqency (Hz)50 / 60
    Output THDv (@Linear Load)<3%
    Mechanical Data
    Dimensions (W × H × D )480x550x250mm
    Weight (kg)32
    Protection Type (in accordance with IEC 60529)IP65
    Installation TypeWall Installation with Wall Bracket
    Communications
    Communication with BMSCAN
    Communication with MeterRS485
    Communication with PortalWiFi
    DisplayLCD, WLAN + APP
    Monitoring SettingsIntegrated data logger
    Other Data
    TopologyTransformerless
    Self-consumption at Night (W)<10
    Warranty5/10 Years