The M-Power S60/125 delivers 60kW of continuous three-phase AC power, enough to run welding equipment, tower cranes, LED screens, telecom base stations, and water purification units simultaneously. Its 125kWh LiFePO4 battery pack provides over two hours of full-load runtime and considerably longer at typical partial loads.
What sets this system apart is its integrated 108kW solar input across 4 MPPT trackers. This is the highest PV capacity in its power class. On a clear day with adequate panel area, the solar array alone can fully recharge the battery while continuing to serve the load. In off-grid mining or construction deployments with consistent sun exposure, this translates to dramatically reduced or eliminated dependence on fuel delivery logistics.
125 kWh
Storage Capacity
60 kW
AC Power Output
200A
Charging & Discharging
5 Years
Product Warranty
2 Units
Max. Parallel
108 kW
Solar Input
IP55
Protection Level
1550*1200*1300
Dimensions (mm)
The M-Power S60/125 accepts power from four independent sources: solar panels (108kW DC), grid connection (AC), diesel generators, and DC charging stations. No other mobile BESS in this power class combines all four charging methods in a single unit.
This flexibility matters in practice. A construction team in an urban area can charge from the grid overnight and run clean power during the day. A mining operation 200 km from the nearest grid connection can pair the unit with solar panels and a diesel backup. An event organizer can pre-charge at a depot via DC fast charging, then deploy a fully charged unit to the venue with zero on-site emissions. The system's built-in energy management automatically prioritizes the lowest-cost source and switches between inputs without manual intervention.
At 1,550 × 1,200 × 1,300 mm and 1,500 kg, the S60/125 is compact enough for standard forklift handling and flatbed transport, yet large enough to house a full 125kWh LFP battery with integrated inverter, BMS, EMS, and optional fire suppression.
The IP55-rated steel enclosure protects all internal components against dust ingress and water jets from any direction. It operates across a temperature range of -20°C to 55°C (with derating above 45°C) and at altitudes up to 3,000 m (with derating above 2,000 m). Intelligent air cooling maintains optimal battery temperature without the complexity and maintenance demands of liquid cooling. The result is a unit that can be deployed to a desert oil field, a tropical construction site, or a Scandinavian winter event without modification.
The S60/125 is not a forced replacement for diesel generators. It is designed to work alongside them. In hybrid mode, the battery handles base loads and peak demands while the generator runs only at optimal load points. This approach reduces fuel use by up to 60%, extends generator service life, and cuts maintenance intervals.
The system's overload capacity (110% continuous, 140% for 10 seconds) handles startup surges from heavy equipment without tripping. During low-load periods, especially overnight on 24-hour sites, the battery takes over entirely and the generator shuts down, eliminating noise and emissions during rest hours.
For operations that are ready to go fully electric, the S60/125 runs independently on battery and solar power alone, producing zero tailpipe emissions.
Two M-Power S60/125 units connect in parallel to deliver 120kW of continuous power and 250kWh of usable energy. The parallel configuration uses automatic load balancing across both units, with no external controller required.
This scalability covers the range from single-unit deployments (60kW for small-to-mid construction sites, film sets, or telecom backup) to dual-unit configurations (120kW for large events, mining camp base loads, or emergency grid support). Rather than purchasing a single large system, operators can start with one unit and add a second when project demands grow.
Rental fleets adding battery-powered units to meet growing customer demand for clean, quiet temporary power. The S60/125's five-year warranty and low maintenance requirements (no oil changes, no fuel filters, no exhaust treatment) support higher rental margins compared to equivalent diesel generators.
Job site power in cities with noise restrictions and low-emission zones. The system provides clean daytime power from battery and solar, with diesel hybrid backup for extended or high-demand periods. On 24-hour sites, the battery handles overnight loads silently while the generator rests.
Silent power for stages, lighting rigs, broadcast equipment, and catering. The S60/125 operates significantly quieter than diesel generators, eliminating the constant noise floor that disrupts performers, audiences, and recording equipment.
Remote operations that depend on diesel generators where fuel transport is the largest single operating expense. Pairing the S60/125 with solar panels and an existing generator reduces fuel logistics and costs while extending generator service intervals.
Rapid-deployment power for field hospitals, water treatment, communication equipment, and temporary shelters. The system charges from any available source and operates immediately upon delivery.
The M-Power S60/125 can be equipped with an optional 20kW DC charging module that charges forklift batteries directly from the unit. This is particularly relevant for construction and warehousing sites where electric forklifts operate alongside the main power load. The charger connects via a 125A DC charging socket and eliminates the need for a separate charging station on site.
BSLBATT manufactures the M-Power series at its 20,000+ sqm production facility with over 3GWh annual capacity. Every unit is assembled, tested, and QC-certified in-house before shipment. The full order-to-delivery cycle takes approximately 8 weeks, covering technical drawing confirmation, raw material procurement, production, testing, packaging, DG approval, and global shipping.
Custom branding, enclosure colors, trailer mounting configurations, and BMS communication profile adjustments are handled at production-line level. BSLBATT's engineering team supports system integration for equipment rental companies, diesel generator distributors, and energy service providers entering the mobile storage market.
BSLBATT manufactures the M-Power S60/125 in China and provides regional logistics and after-sales support through offices and service points in North America (Dallas, TX), Europe, Australia, Africa, and other markets. Contact BSLBATT for project pricing, MOQ, and sample availability.
The M-Power S60/125 includes a 5-year BSLBATT manufacturer warranty covering the battery pack, hybrid inverter, BMS, and all integrated components. Support is factory-backed, with regional service points that can take warranty cases. Ask BSLBATT for the current warranty letter when you need the full terms.
All three M-Power models use LiFePO4 chemistry, IP55 enclosures, and support diesel hybrid operation. The choice depends on power demand, solar strategy, and deployment scale.
| Model | S30/69 | S60/125 | S125/261 |
|---|---|---|---|
| Rated Power | 30 kW | 60 kW | 125 kW |
| Energy Capacity | 69 kWh | 125 kWh | 261 kWh |
| Solar Input | 38.4 kW (2 MPPT) | 108 kW (4 MPPT) | Not supported |
| Cell | 150 Ah | 205 Ah | 314 Ah |
| Cooling | Air | Air | Air + Liquid |
| Parallel | 3 units (90 kW) | 2 units (120 kW) | 2 units (250kW) |
| Weight | 1,012 kg | 1,500 kg | 2,500 kg |
| Dimensions (mm) | 1060 × 1400 × 1030 | 1550 × 1200 × 1300 | 2000 × 1300 × 1560 |
| Warranty | 5 Years | 5 Years | 5 Years |
The M-Power S30/69 is the entry point for light construction, small events, telecom backup, and single-shift operations where loads rarely exceed 20-25kW average. Three units parallel to 90kW for mid-range jobs.
The M-Power S60/125 is the solar-optimized workhorse: it has the highest PV input in the series (108kW), making it the best fit for sites with consistent sun exposure where fuel delivery is expensive or impractical. It covers medium construction, large events, mining camp base loads, and 24-hour operations.
The M-Power S125/261 is the heavy-duty option for high-power industrial loads. Its 314Ah cells and hybrid air-liquid cooling handle sustained discharge at 125kW. It does not support PV input, so it is designed for grid, generator, and DC charging deployments in mining, oil field, and heavy construction scenarios. Two units connect in parallel for 250kW/522kWh.
BSLBATT's M-Power S60/125 stores 125kWh of usable energy. At full 60kW load, runtime is approximately 2 hours. At a typical construction site averaging 20-30kW demand, runtime extends to 4-6 hours. With solar panels connected, the system can operate indefinitely during daylight hours if solar generation meets or exceeds the load.
BSLBATT designed the M-Power S60/125 with simultaneous solar charging and load supply. Its 108kW solar input across 4 MPPT trackers (150V-950V operating range) allows the system to charge and discharge at the same time. In practice, this means the battery is continuously replenished during daylight while providing uninterrupted power to the site.
BSLBATT's M-Power S60/125 works with standard three-phase diesel generators. The system accepts AC input through its 125A three-phase aviation connectors and automatically manages the generator's start/stop cycle based on battery state of charge and load demand. No proprietary generator brand is required.
BSLBATT's M-Power S60/125 and the Generac MBE 60/125 share the same power and capacity class (60kW/125kWh), but differ in three key areas. First, battery chemistry: the S60/125 uses LiFePO4 (lithium iron phosphate), which provides higher thermal stability than the Generac's Li-ion NMC. Second, solar integration: the S60/125 includes a 108kW built-in solar input with 4 MPPT trackers; the Generac supports solar but requires external components. Third, the S60/125 offers an optional 20kW DC forklift charger that no competitor in this class provides.
BSLBATT's M-Power S60/125 holds CE and IEC 62619 certification.
BSLBATT provides a 5-year product warranty on the M-Power S60/125. This covers the battery pack, inverter, BMS, and all integrated components under normal operating conditions.
| Model | M-Power S60 / 125 |
| Battery Parameters | |
| Battery Type | Lithium Iron Phosphate (LFP) |
| Cell Capacity | 3.2V / 205 Ah |
| Configuration | 1P32S×6S (1P192S) |
| Rated Energy | 125.9kWh |
| Rated Charge / Discharge Power | 0.5P (25±2℃) |
| Max Charge / Discharge Current | 200A (25±2℃) |
| Rated Voltage | 614.4V |
| Operating Voltage Range | 537.6V-672.0V |
| PV Side Parameters | |
| Max Input Power | 108kW |
| Start-up Voltage | 180V |
| Operating Voltage Range | 150V-950V |
| Max Input Current | 40Ax4 |
| Max Input Short-circuit Current | 60Ax4 |
| Number of MPPT Trackers | 4 (2+2+2+2) |
| PCS Side Parameters | |
| Rated Powerr | 60kW |
| Max DC Current | 160A |
| DC Operating Voltage Range | DC150-950V |
| Rated AC Voltage | AC380 / 400V, 3W+PE / 3W+N+PE |
| Rated AC Current | 86.6A |
| Rated AC Frequency | 50 / 60Hz (±5Hz) |
| Power Factor | 0.8 leading-0.8 lagging |
| THDI | <3% |
| Overload Capacity | 110%-continuous; 140%-10s |
| External Interfaces | |
| 125A Three-phase Aviation Connector | 3 |
| 16 A Single-phase Socket | 2 |
| 125A DC Charging Socket | 1 |
| DC Output (OPTIONAL) | 20kW Chargerx1 |
| General Parameters | |
| Operating Humidity | 10-90% RH (non-condensing) |
| Operating Temperature | -20℃to 55℃ (derating above 45℃) |
| Storage Temperature | 0℃to 35℃ |
| Altitude | 3000m (derating above 2000 m) |
| Cooling Method | Intelligent air cooling |
| Fire Suppression | Aerosol fire extinguishing systemOPTIONAL |
| Communication | RS485 /CAN / Ethernet / Wi-Fi / 4G / DRY |
| Isolation Type | Non-isolated |
| Protection Rating | IP55 |
| Dimensions (W×D×H,mm) | 1550×1200×1300 (±5mm) |
| Weight | 1500kg ±3% |